Insulation Code FAQ

Closed-Cell Spray Foam R-Value Per Inch (and Open-Cell)

Short answer: The R-value of closed-cell spray foam insulation is R-6.0 to R-7.0 per inch (most products are rated about R-6.5) — the highest R-value per inch of any common insulation. Open-cell spray foam is R-3.5 to R-3.8 per inch. Two inches of closed-cell foam is R-12 to R-14; three inches is R-18 to R-21.

Closed-Cell Spray Foam R-Value Chart by Thickness

Closed-cell spray foam (2 lb/ft³ density) has a rigid, dense cell structure. Multiply the thickness in inches by R-6 to R-7 to get the R-value; the table does the math for common depths. At 2 inches it also acts as an air barrier and a Class II vapor retarder (perm rating <1), and it is the only spray foam suitable for below-grade and exterior applications.

ThicknessR-ValueVapor Retarder?Common Application
1″ (25mm)R-6 to R-7No (>1 perm)Exterior thermal break, flash coat
1.5″ (38mm)R-9 to R-10.5BorderlineRim joists, flash-and-batt walls
2″ (50mm)R-12 to R-14Yes (<1 perm)Basement walls, crawlspaces, rim joists
2.5″ (64mm)R-15 to R-17.5YesBasement walls — meets R-15 continuous (Zones 5–8)
3″ (75mm)R-18 to R-21YesBasement walls, cathedral ceilings
3.5″ (89mm)R-21 to R-24.5Yes2×4 cavity — meets Zone 1–3 wall code
4″ (100mm)R-24 to R-28YesPartial fill of a 2×6 cavity
5″ (125mm)R-30 to R-35Yes2×6 cavity — reaches the R-30 cavity option
5.5″ (140mm)R-33 to R-38.5Yes2×6 cavity, full fill
6″ (150mm)R-36 to R-42YesUnvented roof deck assembly

Why a range? R-value per inch varies by product and blowing agent, and the rated value is an aged figure, since closed-cell foam loses a little R-value in its first years as the blowing agent slowly diffuses. Use the R-value per inch on the manufacturer’s data sheet for code submissions; R-6.5 per inch is a fair planning number.

Open-Cell Spray Foam R-Value by Thickness

Open-cell spray foam expands aggressively (up to 100× its liquid volume) and cures to a soft, spongy foam with open cell structure. Water vapor can pass through it; it is not a vapor barrier.

ThicknessR-ValueAir Barrier?Common Application
2″ (50mm)R-7 to R-7.6PartialUnder-roof deck with additional insulation needed
3.5″ (89mm)R-12.25 to R-13.3Yes2×4 stud cavity (full fill)
5.5″ (140mm)R-19.25 to R-20.9Yes2×6 stud cavity (full fill)
7.5″ (190mm)R-26.25 to R-28.5YesAttic rafter bays (unvented assembly)

Open-Cell vs Closed-Cell: The Key Differences

PropertyOpen-Cell Spray FoamClosed-Cell Spray Foam
R-value per inchR-3.5 to R-3.8R-6.0 to R-7.0
Typical density0.5 lb/ft³2 lb/ft³
Air barrier?Yes (at 3.5″+)Yes (at 1″+)
Vapor barrier?No (vapor-open)Yes (at 2″+)
Water resistanceAbsorbs waterResists water
Structural strength addedMinimalSignificant
Relative costLowerHigher (1.5–2×)
Best applicationInterior walls, atticsBasement walls, unvented roofs, exterior applications

Spray Foam for Specific Applications

Basement Walls

Closed-cell spray foam is the preferred product for below-grade wall insulation. It resists moisture intrusion from the concrete, provides a vapor retarder, and delivers high R-value in a thin profile. Two inches of closed-cell foam on a basement wall (R-12 to R-14) plus a 2×4 stud wall with R-13 batt (R-13) gives a total assembly of R-25+, meeting IECC 2021 basement wall requirements for most zones (R-15 continuous or R-19 cavity + R-5 CI).

Attic Rafter Bays (Unvented Assembly)

For an unvented attic assembly, IECC Table R806.5 specifies minimum closed-cell foam thicknesses on the underside of the roof deck to prevent condensation within the assembly. These minimum thicknesses vary by climate zone:

IECC ZoneMin. Closed-Cell Foam on DeckAdditional Below?
Zones 1–31″ (R-6 to R-7)Open-cell below allowed
Zone 4C (marine)1.5″ (R-9 to R-10.5)Open-cell below allowed
Zones 4A/B and 52″ (R-12 to R-14)Open-cell below allowed
Zone 63″ (R-18 to R-21)Open-cell below allowed
Zone 73.5″ (R-21 to R-24.5)Open-cell below allowed

Air Sealing and Rim Joists

Spray foam (either type) is the most effective air-sealing product available. 2″ of either open- or closed-cell foam at rim joists, sill plate transitions, and around all penetrations eliminates the most common air leakage pathways in typical residential construction. For rim joist insulation alone, closed-cell foam at 2″ provides the vapor retarder function that prevents condensation at this known cold spot.

Cost Comparison

ProductInstalled Cost (approx.)R-Value per Dollar (2×6 wall)
Fiberglass batt R-20$0.40–$0.60/sq ftHighest R/dollar
Open-cell spray foam (5.5″)$1.50–$2.50/sq ftMedium R/dollar; adds air sealing value
Closed-cell spray foam (5.5″)$3.50–$6.00/sq ftLowest R/dollar; highest total performance

Frequently Asked Questions

What is the R-value of closed-cell spray foam per inch?

R-6.0 to R-7.0 per inch, with most products rated around R-6.5. That makes 2 inches about R-13, 3 inches about R-19.5, and a full 2x4 cavity (3.5 inches) about R-21 to R-24.5.

What is the R-value of 2 inches of closed-cell spray foam?

R-12 to R-14. Two inches is also the thickness at which closed-cell foam qualifies as a Class II vapor retarder, which is why it is the standard depth for basement walls and rim joists.

What is the R-value of open-cell spray foam?

R-3.5 to R-3.8 per inch. A full 2x4 cavity (3.5 inches) gives about R-13 and a full 2x6 cavity (5.5 inches) gives about R-20.

What is the R-value of spray foam insulation per inch?

Open-cell spray foam: R-3.5 to R-3.8 per inch. Closed-cell spray foam: R-6.0 to R-7.0 per inch. Closed-cell is the highest R-value per inch of any commonly used insulation product.

What is the difference between open-cell and closed-cell spray foam?

Open-cell is soft, vapor-open (not a vapor barrier), and lower cost. Closed-cell is rigid, acts as a vapor retarder at 2 inches, resists moisture, and provides higher R-value per inch. Open-cell is preferred for interior wall applications; closed-cell for basement walls, unvented roofs, and any exterior application.

Does spray foam meet building code for wall insulation?

Yes. Spray foam is a code-recognized insulation product. Closed-cell foam at 3.5 inches in a 2x4 cavity provides R-21 to R-24.5, exceeding the R-20 wall minimum for Zone 3. Open-cell at 5.5 inches in a 2x6 cavity provides R-19 to R-20. Under IECC 2021, Zones 4-8 also need continuous exterior insulation (R-20+5ci) or an R-30 cavity, which takes about 4.5 to 5 inches of closed-cell foam.

Is spray foam worth the extra cost?

For walls, spray foam’s cost premium over batt insulation is significant. The R-value alone does not justify the premium in most cases. The value case for spray foam is the combination of higher R-value plus the integrated air barrier — no separate air-sealing step required. For rim joists, crawlspaces, and basement walls, spray foam is often the best value product.