Short answer: The R-value of closed-cell spray foam insulation is R-6.0 to R-7.0 per inch (most products are rated about R-6.5) — the highest R-value per inch of any common insulation. Open-cell spray foam is R-3.5 to R-3.8 per inch. Two inches of closed-cell foam is R-12 to R-14; three inches is R-18 to R-21.
Closed-cell spray foam (2 lb/ft³ density) has a rigid, dense cell structure. Multiply the thickness in inches by R-6 to R-7 to get the R-value; the table does the math for common depths. At 2 inches it also acts as an air barrier and a Class II vapor retarder (perm rating <1), and it is the only spray foam suitable for below-grade and exterior applications.
| Thickness | R-Value | Vapor Retarder? | Common Application |
|---|---|---|---|
| 1″ (25mm) | R-6 to R-7 | No (>1 perm) | Exterior thermal break, flash coat |
| 1.5″ (38mm) | R-9 to R-10.5 | Borderline | Rim joists, flash-and-batt walls |
| 2″ (50mm) | R-12 to R-14 | Yes (<1 perm) | Basement walls, crawlspaces, rim joists |
| 2.5″ (64mm) | R-15 to R-17.5 | Yes | Basement walls — meets R-15 continuous (Zones 5–8) |
| 3″ (75mm) | R-18 to R-21 | Yes | Basement walls, cathedral ceilings |
| 3.5″ (89mm) | R-21 to R-24.5 | Yes | 2×4 cavity — meets Zone 1–3 wall code |
| 4″ (100mm) | R-24 to R-28 | Yes | Partial fill of a 2×6 cavity |
| 5″ (125mm) | R-30 to R-35 | Yes | 2×6 cavity — reaches the R-30 cavity option |
| 5.5″ (140mm) | R-33 to R-38.5 | Yes | 2×6 cavity, full fill |
| 6″ (150mm) | R-36 to R-42 | Yes | Unvented roof deck assembly |
Why a range? R-value per inch varies by product and blowing agent, and the rated value is an aged figure, since closed-cell foam loses a little R-value in its first years as the blowing agent slowly diffuses. Use the R-value per inch on the manufacturer’s data sheet for code submissions; R-6.5 per inch is a fair planning number.
Open-cell spray foam expands aggressively (up to 100× its liquid volume) and cures to a soft, spongy foam with open cell structure. Water vapor can pass through it; it is not a vapor barrier.
| Thickness | R-Value | Air Barrier? | Common Application |
|---|---|---|---|
| 2″ (50mm) | R-7 to R-7.6 | Partial | Under-roof deck with additional insulation needed |
| 3.5″ (89mm) | R-12.25 to R-13.3 | Yes | 2×4 stud cavity (full fill) |
| 5.5″ (140mm) | R-19.25 to R-20.9 | Yes | 2×6 stud cavity (full fill) |
| 7.5″ (190mm) | R-26.25 to R-28.5 | Yes | Attic rafter bays (unvented assembly) |
| Property | Open-Cell Spray Foam | Closed-Cell Spray Foam |
|---|---|---|
| R-value per inch | R-3.5 to R-3.8 | R-6.0 to R-7.0 |
| Typical density | 0.5 lb/ft³ | 2 lb/ft³ |
| Air barrier? | Yes (at 3.5″+) | Yes (at 1″+) |
| Vapor barrier? | No (vapor-open) | Yes (at 2″+) |
| Water resistance | Absorbs water | Resists water |
| Structural strength added | Minimal | Significant |
| Relative cost | Lower | Higher (1.5–2×) |
| Best application | Interior walls, attics | Basement walls, unvented roofs, exterior applications |
Closed-cell spray foam is the preferred product for below-grade wall insulation. It resists moisture intrusion from the concrete, provides a vapor retarder, and delivers high R-value in a thin profile. Two inches of closed-cell foam on a basement wall (R-12 to R-14) plus a 2×4 stud wall with R-13 batt (R-13) gives a total assembly of R-25+, meeting IECC 2021 basement wall requirements for most zones (R-15 continuous or R-19 cavity + R-5 CI).
For an unvented attic assembly, IECC Table R806.5 specifies minimum closed-cell foam thicknesses on the underside of the roof deck to prevent condensation within the assembly. These minimum thicknesses vary by climate zone:
| IECC Zone | Min. Closed-Cell Foam on Deck | Additional Below? |
|---|---|---|
| Zones 1–3 | 1″ (R-6 to R-7) | Open-cell below allowed |
| Zone 4C (marine) | 1.5″ (R-9 to R-10.5) | Open-cell below allowed |
| Zones 4A/B and 5 | 2″ (R-12 to R-14) | Open-cell below allowed |
| Zone 6 | 3″ (R-18 to R-21) | Open-cell below allowed |
| Zone 7 | 3.5″ (R-21 to R-24.5) | Open-cell below allowed |
Spray foam (either type) is the most effective air-sealing product available. 2″ of either open- or closed-cell foam at rim joists, sill plate transitions, and around all penetrations eliminates the most common air leakage pathways in typical residential construction. For rim joist insulation alone, closed-cell foam at 2″ provides the vapor retarder function that prevents condensation at this known cold spot.
| Product | Installed Cost (approx.) | R-Value per Dollar (2×6 wall) |
|---|---|---|
| Fiberglass batt R-20 | $0.40–$0.60/sq ft | Highest R/dollar |
| Open-cell spray foam (5.5″) | $1.50–$2.50/sq ft | Medium R/dollar; adds air sealing value |
| Closed-cell spray foam (5.5″) | $3.50–$6.00/sq ft | Lowest R/dollar; highest total performance |
What is the R-value of closed-cell spray foam per inch?
R-6.0 to R-7.0 per inch, with most products rated around R-6.5. That makes 2 inches about R-13, 3 inches about R-19.5, and a full 2x4 cavity (3.5 inches) about R-21 to R-24.5.
What is the R-value of 2 inches of closed-cell spray foam?
R-12 to R-14. Two inches is also the thickness at which closed-cell foam qualifies as a Class II vapor retarder, which is why it is the standard depth for basement walls and rim joists.
What is the R-value of open-cell spray foam?
R-3.5 to R-3.8 per inch. A full 2x4 cavity (3.5 inches) gives about R-13 and a full 2x6 cavity (5.5 inches) gives about R-20.
What is the R-value of spray foam insulation per inch?
Open-cell spray foam: R-3.5 to R-3.8 per inch. Closed-cell spray foam: R-6.0 to R-7.0 per inch. Closed-cell is the highest R-value per inch of any commonly used insulation product.
What is the difference between open-cell and closed-cell spray foam?
Open-cell is soft, vapor-open (not a vapor barrier), and lower cost. Closed-cell is rigid, acts as a vapor retarder at 2 inches, resists moisture, and provides higher R-value per inch. Open-cell is preferred for interior wall applications; closed-cell for basement walls, unvented roofs, and any exterior application.
Does spray foam meet building code for wall insulation?
Yes. Spray foam is a code-recognized insulation product. Closed-cell foam at 3.5 inches in a 2x4 cavity provides R-21 to R-24.5, exceeding the R-20 wall minimum for Zone 3. Open-cell at 5.5 inches in a 2x6 cavity provides R-19 to R-20. Under IECC 2021, Zones 4-8 also need continuous exterior insulation (R-20+5ci) or an R-30 cavity, which takes about 4.5 to 5 inches of closed-cell foam.
Is spray foam worth the extra cost?
For walls, spray foam’s cost premium over batt insulation is significant. The R-value alone does not justify the premium in most cases. The value case for spray foam is the combination of higher R-value plus the integrated air barrier — no separate air-sealing step required. For rim joists, crawlspaces, and basement walls, spray foam is often the best value product.