Faswall 8″ block delivers R-11.3 from its mineralized wood chip aggregate alone — no added foam required. Here’s how it compares to ICF, CMU, and standard concrete for foundation and above-grade walls.
Faswall 8″ block has an R-value of R-11.3. That insulation comes from the wood chip aggregate throughout the block — not from added foam panels. Standard 8″ CMU block has an R-value of about R-1.1, making Faswall roughly 10 times better thermally before any supplemental insulation is added.
Faswall is a stay-in-place insulating concrete form (ICF-style) block made from mineralized wood chips bonded with Portland cement. The wood chips — typically softwood shavings — are treated with a mineral solution that neutralizes their natural sugars and protects them against rot, mold, and insects. The finished block is roughly 60 to 70 percent wood chip by volume, which gives it a much lower thermal conductivity than conventional masonry.
Unlike polystyrene ICF, Faswall blocks can be cut with a standard wood saw, accept screws and nails directly, and can be finished with plaster, stucco, or cladding without furring strips. Concrete is poured into the hollow cores to provide structural strength, while the wood chip matrix provides insulation, sound absorption, and a workable surface.
| Block Size | Wall R-Value | Notes |
|---|---|---|
| Faswall 8″ | R-11.3 | Standard residential block |
| Faswall 8″ + 2″ XPS exterior | ~R-21 | Meets IECC Zone 5–6 above grade |
| Faswall 8″ + 2″ closed-cell spray foam interior | ~R-24 | Also adds vapour control |
| Faswall 8″ + 2″ XPS + R-14 batt interior | ~R-32 | Exceeds Zone 7–8 requirements |
R-values for combined assemblies are approximate. Use the calculator below to build your exact assembly and check compliance for your climate zone.
Add Faswall block plus your supplemental insulation layers and get a pass/fail against IECC 2021.
| Wall System | R-Value (bare block) | Structural | Workability |
|---|---|---|---|
| Standard CMU 8″ | ~R-1.1 | Yes | Standard masonry tools |
| CMU 8″ core-filled EPS | ~R-3.9 | Yes | Standard masonry tools |
| Faswall 8″ | R-11.3 | Yes (cored) | Cuts like wood |
| ICF Standard (Fox Blocks / Nudura) | R-22 | Yes (cored) | Polystyrene — requires special fasteners |
| ICF Plus / XR35 Nudura | R-35 | Yes (cored) | Polystyrene — requires special fasteners |
| Poured concrete 8″ | ~R-0.8 | Yes | Formed — requires forming system |
In most North American climate zones, Faswall at R-11.3 falls short of the IECC 2021 minimums for above-grade walls as a standalone assembly. IECC 2021 Table R402.1.3 requires the following for mass walls (which Faswall qualifies as):
| IECC Climate Zone | Mass Wall R-Value Required | Faswall 8″ Alone |
|---|---|---|
| Zone 1–2 | R-3 | ✓ Passes |
| Zone 3 | R-5 | ✓ Passes |
| Zone 4 (except Marine) | R-8 | ✓ Passes |
| Zone 4 Marine & Zone 5 | R-13 | ✗ Add insulation |
| Zone 6 | R-15 | ✗ Add insulation |
| Zone 7–8 | R-19 | ✗ Add insulation |
Mass walls receive slightly more favourable treatment under IECC because their thermal mass slows heat transfer over time, providing benefits that a simple R-value does not fully capture. The table above uses the IECC mass wall column. If your jurisdiction uses prescriptive framed-wall requirements instead, the minimums are higher and Faswall will need supplemental insulation in Zone 4 and above.
Faswall is approved for use as both above-grade and below-grade foundation walls. For below-grade applications, the standard approach is to apply exterior XPS rigid foam insulation and a waterproofing membrane before backfilling, the same as you would with a CMU or poured concrete foundation.
The wood chip content in Faswall is mineralized to resist moisture absorption, but the exterior face should still be protected against sustained ground contact with a proper drainage and waterproofing system. Interior spray foam or rigid foam can bring a below-grade Faswall wall to code in Zones 5 through 8 without excavation.
Faswall’s biggest practical advantage over polystyrene ICF is workability. The block cuts cleanly with a standard circular saw or reciprocating saw, accepts common framing fasteners, and can be shaped around openings without specialized ICF tools. Electrical and plumbing runs can be carved directly into the block face with a router or angle grinder.
The exterior surface accepts stucco, plaster, and cementitious coatings directly without a bonding agent — the wood chip texture provides mechanical adhesion. Interior surfaces can be drywalled over furring strips or finished directly with plaster.
Faswall blocks are typically laid in a running bond pattern with a Portland cement mortar or a specialized Faswall mortar mix. Vertical and horizontal reinforcing steel is placed in the cores before concrete is poured, following standard ICF structural design practice.
What is the R-value of Faswall block?
Faswall 8″ block has an R-value of R-11.3. This comes from the mineralized wood chip aggregate throughout the block, not from added foam. Standard 8″ CMU is approximately R-1.1 by comparison.
What is Faswall made of?
Mineralized softwood chips bonded with Portland cement. The wood chips are treated to resist rot, mold, and insects. The block is approximately 60–70% wood chip by volume, with hollow cores that are filled with concrete after the block wall is erected.
Does Faswall meet building code for insulation?
On its own, Faswall 8″ (R-11.3) meets IECC mass wall requirements in Zones 1 through 4 (non-marine). In Zones 5 through 8, supplemental insulation is required — typically 1.5″ to 3″ of XPS or closed-cell spray foam to reach R-13 to R-19.
How does Faswall compare to ICF?
ICF (polystyrene foam forms) achieves R-22 to R-35 depending on type, significantly outperforming Faswall’s R-11.3. However, Faswall cuts like wood, accepts fasteners directly, and accepts plaster and stucco finishes without bonding agents — advantages that matter on certain projects.
Can you use Faswall for foundation walls?
Yes, for both above-grade and below-grade foundation walls. Below grade, apply a waterproofing membrane and exterior rigid foam insulation before backfilling, the same as any masonry foundation. The mineralized wood chip content resists moisture but is not a substitute for proper waterproofing.