BC Building Code 2018 · Section 9.36 · BC Energy Step Code

BC Insulation Requirements

BC spans some of the most diverse climates in Canada — from mild coastal zones to cold northern interior. Insulation requirements vary significantly by location, and the BC Energy Step Code adds another layer that many municipalities now require.

BC Building Code 2018 Section 9.36 sets prescriptive minimums: RSI 8.67 (R-49) for attics, RSI 3.08–3.52 (R-17.5–R-20) for above-grade walls, and RSI 1.76 (R-10) for basement walls — varying by climate zone. Many BC municipalities also require compliance with the BC Energy Step Code, which sets higher whole-building performance targets.

BC's Two Compliance Paths

BC residential construction can meet energy requirements in two ways:

1. Prescriptive Path (BC Building Code Section 9.36)

Meets minimum insulation values for each assembly type by climate zone. Simpler to apply — just hit the numbers for your zone. This is what most of this guide covers.

2. BC Energy Step Code

A performance-based path that evaluates the whole building’s energy use (EnerGuide rating) rather than individual assembly values. Steps 1 through 5 progressively increase performance requirements. Step 1 equals the base code. Steps 3–4 are now required in many Metro Vancouver municipalities and others province-wide by provincial deadline.

If your municipality requires Step 3 or higher, the prescriptive values below may not be sufficient on their own — you’ll need to work with an energy advisor and a blower door test.

⚠️ Check your municipality first: BC has one of the most complex local energy code landscapes in Canada. Vancouver uses its own by-law. Many municipalities require Step 3 or Step 4. Always confirm requirements with your local building department before design.

BC Climate Zones

BC uses Heating Degree Day (HDD) zones based on location. The province spans zones 4 through 8:

City / RegionApprox. HDD (18°C)Climate Zone
Victoria~2,700Zone 4
Vancouver / Lower Mainland~2,800Zone 4–5
Kelowna~3,300Zone 5
Kamloops~3,500Zone 5–6
Cranbrook~4,200Zone 6
Prince George~4,700Zone 6–7
Fort St. John~5,500Zone 7
Atlin / Northern BC~6,500+Zone 8

Prescriptive Insulation Requirements by Zone

The following are minimum values from BC Building Code 2018 Section 9.36. Warmer coastal zones have lower requirements; colder interior and northern zones have higher requirements.

AssemblyZone 4–5 (Coast)Zone 6–7 (Interior)
Attic / ceiling with atticRSI 8.67 (R-49)RSI 8.67 (R-49)
Cathedral ceilingRSI 5.29 (R-30)RSI 5.29 (R-30)
Above-grade wallsRSI 3.08 (R-17.5)RSI 3.52 (R-20)
Basement walls (below grade)RSI 1.76 (R-10)RSI 1.76 (R-10)
Exposed floor over unheated spaceRSI 3.87 (R-22)RSI 4.67 (R-26.5)
Slab-on-grade edgeRSI 1.76 (R-10)RSI 1.76 (R-10)
Check Your Wall Assembly

Build your assembly layer by layer and get an instant pass/fail.

Open calculator →

Vancouver and Metro Vancouver

The City of Vancouver operates under its own Vancouver Building By-law (VBBL) and Zero Emissions Building Plan (ZEBP), which are more stringent than the BC Building Code. New residential buildings in Vancouver are subject to near-zero emissions requirements that go well beyond the prescriptive values above.

Other Metro Vancouver municipalities (Burnaby, Surrey, Richmond, North Vancouver, etc.) follow the BC Building Code but many have adopted BC Energy Step Code requirements at Step 3 or Step 4 for new residential construction. Check with your municipality directly.

BC Energy Step Code — What It Means in Practice

If your project is subject to Step 3 or higher, the prescriptive insulation values are a starting point, not the finish line. Step Code compliance is evaluated on whole-building energy performance, which means:

The Step Code is moving BC toward net-zero ready construction by 2032. The prescriptive path alone won’t get there — the Step Code is where the real performance gains are achieved.

Basement Insulation in BC

BC’s coastal zones see much milder winters than Alberta or Ontario, which affects basement insulation strategy. In Zone 4 (Vancouver area), a basement wall with R-10 meets the prescriptive minimum. In practice, many builders insulate to R-17 or higher for comfort and moisture control.

Moisture management is a bigger consideration in coastal BC than in drier inland climates. Spray foam against the foundation wall is increasingly preferred over batt insulation in a stud wall because it eliminates the condensation risk at the cold concrete surface.

Model Your Assembly

Layer-by-layer R-value calculator — see how your assembly stacks up.

Open calculator →

Frequently Asked Questions

What is the minimum attic insulation in BC?

RSI 8.67 (approximately R-49) for ceilings with attic space under BC Building Code 2018 Section 9.36, across most climate zones. Cathedral ceilings require RSI 5.29 (R-30).

What R-value is required for walls in BC?

RSI 3.08 (R-17.5) in coastal zones 4–5, RSI 3.52 (R-20) in colder interior zones 6–7. BC Energy Step Code may require higher performance depending on your municipality.

What is the BC Energy Step Code?

A performance-based energy standard with 5 steps above the base code. Many BC municipalities now require Step 3 or Step 4 for new residential construction. It focuses on whole-building energy performance rather than individual assembly R-values.

What building code applies in BC?

The BC Building Code 2018 (with 2024 updates), based on the National Building Code of Canada. Vancouver uses its own Vancouver Building By-law. Energy requirements are in Part 9, Section 9.36.

Does Vancouver have different insulation requirements?

Yes. The City of Vancouver uses the Vancouver Building By-law and Zero Emissions Building Plan, which are more stringent than the BC Building Code. Other Metro Vancouver municipalities often require BC Energy Step Code at Step 3 or higher.

What insulation is required for a basement in BC?

RSI 1.76 (approximately R-10) for basement walls under the prescriptive path. Higher values are common in colder interior zones and under Energy Step Code compliance paths.

Related Guides

Ontario Insulation Requirements — Alberta Insulation Requirements — What R-Value Do I Need for My Attic? — Build Code Calculator